Exam calculations, one topic at a time

Every article has a worked example with real numbers and the NEC article or table where each value comes from.

AMPACITY /

Ampacity With 9 Conductors in One Conduit: Derating Worked Example

Nine current-carrying 10 AWG THHN conductors at 40°C: start at 90°C, apply 0.91 and 0.70, then check the terminal. The answer is 25.48 A.

GROUNDING /

Main vs System vs Equipment Bonding Jumper: What Is the Difference?

Main, system and equipment bonding jumpers compared side by side: what each one joins, where it is used, and how to tell them apart on the exam.

MOTORS /

Motor Overload Protection Sizing: NEC 430.32, 125% vs 115%

Size motor overload protection from the nameplate under NEC 430.32: when 125% applies, when 115% applies, and a full worked example.

CODE RULES /

Working Space Clearances Under NEC 110.26: Quiz and Checklist

Width, height, depth, doors and storage around electrical equipment under NEC 110.26, with a seven-question quiz and a one-page checklist.

CODE RULES /

Tap Rules Compared: 10 ft vs 25 ft Under NEC 240.21(B)

The 10 ft and 25 ft feeder tap rules side by side: length, one tenth versus one third, where each tap ends, with worked sizing on a 400 A feeder.

AMPACITY /

Terminal Temperature Ratings: 60°C vs 75°C Ampacity, Worked Examples

Which ampacity column do you use? NEC 110.14(C) explained with three worked examples: the 60°C column, the 75°C column, and starting from 90°C.

CODE RULES /

Grounding Electrodes: What Counts Under NEC 250.52, Myth vs Fact

Which electrodes count in the grounding electrode system? Six common myths checked against NEC 250.50, 250.52 and 250.53, with the key numbers.

PULL BOXES /

Pull Box Sizing: Straight Pull and Angle Pull Worked Example

Size a pull box step by step: the 8 times rule for straight pulls and the 6 times plus others row method for angle pulls, with a full worked box.

OVERCURRENT /

Standard Breaker Sizes and the Next Size Up Rule: Common Mistakes

The standard ratings in 240.6(A) and the next size up rule in 240.4(B), with a worked example and the six mistakes that cost exam points.

GROUNDING /

EGC vs GEC Sizing: Table 250.122 vs Table 250.66

Which table sizes which grounding conductor? Compare NEC Table 250.122 and Table 250.66 side by side, with one 200 A panel worked both ways.

GFCI AND AFCI /

GFCI vs AFCI: Where Each Is Required, Myth vs Fact

GFCI protects against shock and AFCI against arcing fires. See where each applies in dwellings, five common myths, and what changed by NEC edition.

RECEPTACLE LAYOUT /

The 12-Foot Receptacle Rule: A Seven-Question Quiz

Test yourself on the dwelling unit 6 foot and 12 foot receptacle spacing rule in NEC 210.52(A) with seven quiz questions and plain answers.

PARALLEL CIRCUITS /

Parallel Circuit Resistance: Worked Examples, Two Methods

Calculate parallel resistance with product over sum and the reciprocal method. Five worked examples, current and power checks, and common mistakes.

CONTINUOUS LOAD /

Continuous Load: The 125 Percent Rule, Worked Step by Step

How the 125 percent continuous load rule sizes branch circuit conductors and breakers, with four worked examples and the mistakes that cost exam points.

POWER LOSS /

Why 240 V Needs Half the Current and One Quarter the Wire Loss

For the same watts, doubling the voltage halves the current and cuts I squared R wire loss to one quarter. Worked 120, 240 and 480 V comparison for the exam.

NEUTRAL FAULTS /

Open Neutral on 120/240 V: Why One Load Gets More Than 120 V

When the neutral opens, two loads share 240 V in proportion to resistance and the smaller load gets more. Worked example, table and a real incident report.

RESISTANCE /

Wire Resistance: Length, Size, Copper vs Aluminum and Temperature

Resistance of a conductor from length, area, material and temperature, with worked copper and aluminum examples and a link to the K value in voltage drop.

WIRE SIZES /

AWG and Circular Mils: The Rule of 3 and the Rule of 10

Every 3 AWG sizes doubles the area, every 6 doubles the diameter, every 10 multiplies area by about ten. Worked checks against a wire table and a voltage drop link.

CONVERSIONS /

kW, Horsepower and BTU/h Conversions for the Electrician Exam

The factors for kW, hp and BTU/h, the direction rule, and worked problems for heaters, water heating and AC tons, with sources from NIST, EIA and USGS.

SINGLE-PHASE /

Neutral Current on a 120/240 V Circuit: The Difference Rule

The neutral carries only the difference between the two legs. Worked 120/240 V examples, a table of four cases, and the mistakes to avoid on the exam.

THREE-PHASE /

Wye vs Delta: Line and Phase Voltage and Current Explained

Which 1.732 goes where? Wye and delta rules for line and phase voltage and current, with three worked problems for the electrician exam.

EXAM MATH /

Power Factor: kW, kVA and Amps, Worked Step by Step

Convert kW to kVA to amps with power factor, single-phase and three-phase, with worked examples and a practice question.

VOLTAGE DROP /

How to Calculate Voltage Drop for the Electrician Exam

Voltage drop for the journeyman exam: single-phase and three-phase formulas, where K and CM come from, and four worked problems with every step.

CONDUIT FILL /

Conduit Fill Calculation, Step by Step

How to calculate conduit fill with NEC Chapter 9 Tables 1, 4 and 5: the 53/31/40 rule, the 0.8 rounding rule, and three worked EMT examples.

BOX FILL /

Box Fill Calculation Examples (NEC 314.16)

Box fill counting rules from NEC 314.16 in plain terms, with worked examples for receptacle boxes, switch boxes and mixed conductor sizes.

LOAD CALCULATIONS /

Residential Load Calculation: The Standard Method

A full dwelling load calculation using the NEC standard method: lighting, small appliance, demand factors, range, dryer, appliances, heat or AC, service size.

OHM'S LAW /

Ohm's Law and Power Formulas for Electricians

Ohm's law and power formulas with worked problems: heater current, a 240 V element on 208 V, parallel resistance, power factor and three-phase power.

AMPACITY /

Ampacity and Derating: Temperature and Bundling

How to derate conductor ampacity for ambient temperature and more than three current-carrying conductors, then check terminals. Three worked examples.

MOTORS /

Motor Circuit Calculations: FLC Tables, Overloads and Branch Circuits

Motor circuit basics for the exam: table FLC vs nameplate, 125% conductors, overload sizing, Table 430.52 breakers and fuses, and a multi-motor feeder.

TRANSFORMERS /

Transformer Sizing and kVA Calculations

Transformer kVA and current formulas for single-phase and three-phase, sizing a transformer for a load, and overcurrent protection with Table 450.3(B).

THE EXAM /

How the Journeyman Exam Is Scored and Timed

What to look up for your state's journeyman exam: items, time, passing score, code edition and references, with Texas and Wisconsin examples from official pages.

MISTAKES /

Common Calculation Mistakes on the Journeyman Exam

Ten setup mistakes that cost points on journeyman exam calculations, each with the wrong answer and the right one: voltage drop, motors, fill, derating, load calcs.